Accuracy Class |
C3 |
C2 |
0.05 |
Units |
---|---|---|---|---|
Rated Capacities |
3, 5, 10, 20 ,25, 30, 50 |
Tonne |
||
Rated Output |
2.0 ± 0.004 |
mV/V |
||
Creep at rated output |
±0.0245 |
±0.0245 |
±0.05 |
%FS/30min |
Temperature effect on output |
±0.007 |
±0.010 |
±0.025 |
% of applied load/5C |
Temperature effect on zero |
±0.007 |
±0.009 |
±0.025 |
% of rated output/5C |
Safe Overload |
150 |
% of rated Capacity |
||
Ultimate overload |
200 |
% of rated Capacity | ||
Recommended excitation |
10 |
Volts DC |
||
Maximum excitation |
15 |
Volts DC |
||
Input impedance |
800±30 |
Ohms |
||
Output impedance |
701.5 ±4.5 |
Ohms |
||
Insulation Resistance |
>5000 |
Megaohms |
||
Environmental protection |
IP68 (Hermetically sealed) |
|||
Cable |
13 meters. 10T = 9 meter |